Emerson White Rodgers 1F95-0671 Installation Manual
Blue Universal Thermostat with Automatic Heat/Cool Changeover Option
Model 1F95-0671 7 Programming Choices Day 5/1/1 Day Non-Programmable
PART NO. 37-6979B
Replaces 37-6979A
Emerson 1F95-0671 Spesification
Electrical Rating:
Battery Power = mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire = 20 to 30 VAC
Terminal Load = 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range = 45 to 99°F (7 to 32°C)
Differential (Single Stage) = Heat 0.6°F; Cool 1.2°F
Differential (Multi-Stage) = Heat 0.6°F; Cool 1.2°F
Differential (Heat Pump) = Heat 1.2°F; Cool 1.2°F
Operating Ambient = 32°F to +105°F (0 to +41°C)
Operating Humidity = 90% non-condensing max.
Shipping Temperature Range = -40 to +150°F (-40 to +65°C)
Dimensions Thermostat = 4.2"H x 6.4"W x 1.7"D
Emerson 1F95-0671 Power Stealing Switch
The Power Stealing Switches (Figure 1, rear view) should be left in the "On" position for most systems. The information in the following table details the thermostat power method and switch options.
Thermostat Power Method |
Switch Position/Description |
Battery Powered, no 24 Volt system power available. |
Switches "On", thermostat runs on batteries. |
Hardwired with Battery Back-up, for 24 Volt systems with common connection from transformer to "C" terminal on thermostat. |
Switches "On", thermostat runs on power directly from transformer with battery back-up. |
*Battery Powered with Power Stealing Assist, for 24 Volt systems with no common connection from transformer to "C" terminal on thermostat. |
Switches "On", thermostat runs on batteries and supplemental power drawn through the heat or cool circuit. |
*Power Stealing Assist is very reliable to increase battery life, but on a small number of heating or cooling systems with high impedance electronic modules you may observe one of the following conditions:
- The furnace draft inducer motor may run with no call for heat.
- The furnace fan may turn on with no call for heat or may not turn off.
- The furnace may not turn off when the call for heat ends.
- The air conditioner may not turn off when the call for cool ends.
If the Power Stealing Assist method is not compatible with your system, place the Power Stealing Switches to "Off". This cancels Power Stealing Assist, operates the thermostat on batteries and corrects the condition.
Emerson 1F95-0671 WIRING DIAGRAMS
Refer to equipment manufacturers' instructions for specific system wiring information. After wiring, see CONFIGURATION section for proper thermostat configuration. Wiring diagrams shown are for typical systems and describe the thermostat terminal functions.
Emerson 1F95-0671 TERMINAL DESIGNATION DESCRIPTIONS
O/B = Changeover valve for heat pump energized constantly in cooling and off/heating
Y2 = 2nd Stage Compressor
Y = Compressor Relay
G = Fan Relay
RC = Power for Cooling
RH = Power for Heating
C = Common wire from secondary side of cooling (Optional). Required for fault indication, continuous backlight operation or remote temperature sensor operation 6 Powered closed 3rd wire for 3-wire zone valve
W/E = Heat Relay/Emergency Heat Relay (Stage 1) (3rd Stage Heat in HP2)
W2 = 2nd Stage Heat (4th Stage Heat in HP2)
- = Common (DC) for wired remote temperature sensor
S = Frequency signal from remote temperature sensor
+ = Power (DC) to remote temperature sensor
L = Compressor diagnostic indicator for systems with diagnostic connection typically found on Heat pump systems or with Copeland's Comfort Alert
Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer
Emerson 1F95-0671 Single Stage and Multi-Stage Connections
Refer to equipment manufacturers' instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or two-transformer system. You can configure the thermostat for use with the following
systems:
Single stage (SS 1) gas, oil or electric.
Multi-stage (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.
Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers
Emerson 1F95-0671 WIRING Heat Pump Systems
Emerson 1F95-0671 Heat Pump Connections
Refer to equipment manufacturers' instructions for specific system wiring information. This thermostat is designed to operate a single-transformer or two-transformer system.
You can configure the thermostat for use with the following
systems:
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas or electric backup.
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two compressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for proper thermostat configuration.
Emerson 1F95-0671 Wire (SPDT) Heat Only Zone Valve Wiring
Emerson 1F95-0671 Programming & Configuration Items
Programming and Configuration Items
- "System On" indicates when heating or cooling stage is energized. "System On +2" indicates when addi tional stages are on.
- The word "Hold" is displayed when the thermostat is in the HOLD mode. "Temp" is displayed when the thermostat is in a Temporary HOLD mode.
- Displays "Change Filter" when the system has run for the programmed filter time period as a reminder to change or clean your filter.
- Displays "Set" for setpoint when in Run Program mode.
- Displays System Mode (Heat, Em, Auto, Cool, Off) or Time in menu mode.
- Displays Fan mode (On, Auto) "Prog FAN On" or "Run Sched" in Menu mode.
- Displays "Run Schedule", "Schedule", or "Menu".
- Displays "Save" when Cool SavingsTM is working.
- Displays "Heat Pump" when system is configured as Heat Pump thermostat.
- Displays "Hold" in programmable mode when not in Hold mode. Displays Light Bulb in non-programmable mode.
- Initially displays "Auto Sched". If Auto Schedule had been used or disabled, then it displays "Cool Savings" when in the Cool Mode. Displays "Copy" in Schedule mode and "Fan" in Fan Schedule mode.
- "Call For Service" indicates a diagnostic fault in the heating/cooling system, it does not indicate a fault in the thermostat.