Verdant VX-TW-KT-W Wireless Energy Management Thermostat Product Specifications Guide
Verdant VX-TW-KT-W Wireless Features
- Easy-to-use Thermostat
- Unparalleled Energy Savings
- Uncompromising Guest Comfort
- Quick-and-Easy Installation
- Auxiliary output that allows for integration with make-up air units, lighting, and other devices.
- Remote Management Capabilities*
The Verdant VX Series Thermostat delivers unprecedented energy savings without compromising guest comfort. An integrated occupancy sensor allows for energy saving when rooms are
unoccupied. Energy saving presets eliminate guesswork and make it easy to adjust the energy saving settings. A patented “Night Occupancy” feature ensures comfort while guests are sleeping. Built-in wireless mesh-networking enables optional remote management features. Fully configurable settings allow for customization of energy savings to fi t any situation.
- Temperature Setback automatically adjusts the temperature when rooms are unoccupied to save energy.
- Temperature Recovery allows for setting a maximum time permitted for establishing a comfortable room temperature.
- Setback Optimization monitors the temperature recovery rate and optimizes setback temperatures.
- Setback Limits control the maximum and minimum room temperature when a room is in setback mode.
- Set Point Limits prevent guests from setting the room temperature to extreme, energy-wasting levels.

Control Card Installation - Wiring Table
Wiring Table - 24V AC
| Wire Color | Terminal Letter | Terminal Connection | 
| BLACK | C | COMMON | 
| RED | R | 24V | 
| YELLOW | Y | COMPRESSOR | 
| WHITE | W | HEAT | 
| ORANGE | O OR B | REVERSE VALVE | 
| GREEN | GH | FAN HIGH | 
| PURPLE | GL | FAN LOW | 
| BROWN | AUX | OCCUPANCY OUT | 
Wiring Table - 24V DC
| Wire Color | Terminal Letter | Terminal Connection | 
| BLACK | R | 24V | 
| RED | C | COMMON | 
| YELLOW | Y | COMPRESSOR | 
| WHITE | W | HEAT | 
| ORANGE | O OR B | REVERSE VALVE | 
| GREEN | GH | FAN HIGH | 
| PURPLE | GL | FAN LOW | 
| BROWN | AUX | OCCUPANCY OUT | 
Optional AC/DC Power Installation
Wiring Table - 24V AC
| Wire Color | Terminal Letter | Terminal Connection | 
| BLACK | C | COMMON | 
| RED | R | 24V | 
Wiring Table - 24V DC
| Wire Color | Terminal Letter | Terminal Connection | 
| BLACK | R | 24V | 
| RED | C | COMMON | 
Verdant VX-TW-KT-W Wireless Energy Management Thermostat Product Specifications
| Thermostat | Wireless Control Card | |
| Case Dimensions (Imperial) | 4.02 x 5.51” x 0.93” | 3.875” x 2.125” x 0.75” | 
| Case Dimensions (Metric) | 102mm x 140mm x 23.5mm | 98mm x 54mm x 19mm | 
| Screen Dimensions (Imperial) | 3.63” x 2.13” | N/A | 
| Screen Dimensions (Metric) | 92mm x 54mm | N/A | 
| Operating Voltage | 3V DC - 2 "AA" Cell Batteries | 24V AC/DC (HVAC Unit) | 
| Control Outputs | 
 | Fan High (GH) | 
| 
 | Fan Low (GL) | |
| 
 | Compressor (Y) | |
| 
 | Heat Pump (OB) | |
| 
 | Heat (W) | |
| 
 | 
 | Occupancy Out (Aux) | 
| Occupancy Sensor Beam Width | ±47° (94°) | N/A | 
| Wireless Frequency | 902-928MHz | 902-928MHz | 
| Temperature Accuracy | ±1°F | N/A | 
| FCC ID | XEYWX | XEYV8ACCC | 
| IC | 8410A-WX | 8410A-V8ACCC | 