Emerson 1F83C-11PR Instruction Manual
Emerson 1F83C-11PR Spesification
Electrical Rating:
Battery Power........mV to 30 VAC, NEC Class II, 50/60 Hz
Input-Hardwire.....20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load......1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range....45° to 99° F (7° to 37° C)
Rated Differentials: Fast Med Slow
Heat (@ 6°F/ Hr)..... 0.5°F 0.75°F 1.9°F
Cool (@ 6°F/ Hr).....0.9°F 1.2°F 1.7°F
Operating Ambient..... 32°F to +105°F (0° to +41°C)
Display Temperature Range..... 32°F to +99°F (0 to 37°C)
Operating Humidity....90% non-condensing max
Shipping Temperature Range...-20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions........3-3/4” H x 6” W x 1-1/8” D
THERMOSTAT OVERVIEW
Before you begin using your thermostat, you should be familiar with its features, display and the location/operation of the thermostat buttons and switches.
THERMOSTAT BUTTONS AND SWITCHES |
THE DISPLAY |
1.) Fan Switch |
10.) Thermostat is protecting the equipment from short cycling (5-minute delay) |
2.) System Switch |
11.) Indicates that the system is running in cool or heat |
3.) Backlight Button (located on the top of the thermostat |
12.) Displays the current time |
4.) Set Correct Time |
13.) Battery status indicator |
5.) Hold a Permanent Temperature |
14.) Low battery indicator |
6.) Cancels Hold – Returns to Programmed Schedule |
15.) Day of the week used when programming a schedule |
7.) Raises Temperature Setting |
16.) Permanent hold (bypassing the schedule) |
8.) Access Menu Options |
17.) Temperature setpoint |
9.) Lowers Temperature Setting |
18.) Appears when the keypad is locked (to prevent unwanted changes) |
|
19.) Next (Menu button) is used to navigate within a menu |
|
20.) Access the schedule and customize thermostat features |
|
21.) Back (Run button) is used to navigate within a menu |
|
22.) Exit (Hold button) returns to the home screen |
|
23.) SEE TROUBLESHOOTING |
Emerson 1F83C-11PR THERMOSTAT SCHEDULE
Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for all days of the week.
|
Wake |
Leave |
Return |
Sleep |
Heating Schedule |
6:00 AM - 70°F |
8:00 AM - 62°F |
5:00 PM - 70°F |
10:00 PM - 62°F |
Cooling Schedule |
6:00 AM - 75°F |
8:00 AM - 83°F |
5:00 PM - 75°F |
10:00 PM -78°F |
Modify the Heating Schedule
- Slide the system switch to Heat
- Press Menu
- Press Next to enter the schedule
- The time icons will flash – use up or down to set the time for the start of a period
- Press Next – the set point icons will flash – use up or down to set the temperature for the current period
- Continue to press Next to advance through all periods (Wake, Leave, Return, Sleep) for all days of the week.
Note: Press Back to return to the previous setting. Once all days of the week have been programmed the thermostat will display End. Press Exit at any time to save changes and return to home screen.
Modify the Cooling Schedule
- Slide the system switch to Cool
- Repeat steps 2-6 from the heating schedule
TROUBLESHOOTING
Symptom |
Possible Cause |
Corrective Action |
No Heat/ No Cool/ No Fan (common problem) |
|
|
No Heat |
|
Verify thermostat and system wires are securely attached. Diagnostic: Set System Switch to Heat and raise the setpoint above room temperature. Within five minutes the thermostat should make a soft click sound and “Heat On” should appear on display. This sound indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed below. If the thermostat does not click after being reset, contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly. |