EMERSON White Rodger Single Stage Thermostat Installation Guide

EMERSON White Rodger Single-Stage Thermostat with 5-1-1 Day scheduling Install Guide

EMERSON White Rodger Single Stage Thermostat PREPARATIONS

Check package contents

This package should contain the following items:

  • Thermostat
  • Mounting screws and wall anchors (x2)
  • 2 AAA batteries
  • Terminal wire label stickers
  • Installation instructions

 Gather tools

Required tools:

  • Flat-head Screwdriver
  • Small pliers (needle-nose)
  • Drill with 3/16” (4 mm) bit

Optional tools:

  • Wire cutters/stripper
  • Hammer

THERMOSTAT DETAILS

The thermostat buttons and switches

EMERSON White Rodger Single-Stage Thermostat

  • Raises temperature setting.
  • Lowers temperature setting.
  • TIME button.
  • PRGM (program) button.
  • RUN (run program) button.
  • HOLD temperature button.
  • FAN switch (ON, AUTO).
  • SYSTEM switch (COOL, OFF, HEAT). 

Terminal labeling reference chart

If your current terminal has the following letter

Label the wires with the following letters

Terminal function

RH, R, R5, 5

RH

24V Power (Heating)

RC

RC

24V Power (Cooling)

W, W1, 4

W

Heating Relay

Y, Y1

Y

Cooling Relay

G

G

Fan Relay

O

O

Reversing Valve (for heat pump applications energized in Cool mode)

B

B

Reversing Valve (for heat pump applications energized in Heat mode)

Identify jumper wire

On your old thermostat, if…

Then, on your new thermostat…

Terminal RC and RH are connected with a jumper wire

Leave the jumper wire in its place

There’s only one R wire (RC, RH, R or R5) coming out of the wall

Leave the jumper wire in its place

Terminal RC and RH (or 5 or R5) are NOT connected by a jumper wire

Remove the jumper wire between RC and RH

For terminal Y and W:
If you have a heat pump with reversing valve, connect Y and W with a jumper wire on your new thermostat.

Remove old thermostat base

With all of your wires disconnected and properly labeled, you may now safely remove the thermostat base from your wall. 

Remove old thermostat base

MOUNTING AND WIRING YOUR NEW THERMOSTAT

Install new thermostat base

Install new thermostat base

Mount your new thermostat base using the supplied screws. Drill holes and insert wall anchors to secure the thermostat base to the wall, if necessary.

Connect wires to corresponding terminal blocks

Match each labeled wire to it’s corresponding terminal on the mounted thermostat base. Insert each labeled wire into the hole of it’s matching terminal, and using the screwdriver, tighten the screw on the terminal block securely.

Set switch and advanced wiring

Set switch and advanced wiring

If you have either a gas or oil furnace, set the switch to GAS. If you have an electric furnace, set the switch to ELEC.