Thermostat can be mounted on 2" x 4" J box or on drywall or plaster using included wall anchors (drill 3/16" holes for drywall; 7/32" holes for plaster). Connect 1, 2, 3 terminals on thermostat to 1, 2, 3 terminals on EIM or Zone Panel; see EIM or Zone Panel Installation Guide for wiring diagrams.

Honeywell TH9421C1004 Installation

Thermostat can be mounted on 2" x 4" J box or on drywall or plaster using included wall anchors (drill 3/16" holes for drywall; 7/32" holes for plaster). Connect 1, 2, 3 terminals on thermostat to 1, 2, 3 terminals on EIM or Zone Panel; see EIM or Zone Panel Installation Guide for wiring diagrams.

Setup function Settings & options (factory default in bold)

0110

Zone number

0

1–9

Not zoned

Zone number

0120

Year

20

(2000-2099)

 

(first two digits)

21

(2100-2178)

0130

Year

(second two digits)

06

(2006)

[Other options: 00-99]

0140

Month

6

[Other options: 1-12]

0150

Date

15

[Other options: 1-31]

0160

Schedule format

4

7-day programming

 

 

0

Non-programmable

0165

Restore Energy

0

No

 

Star schedule

1

Yes

0172

System type

1

Conventional

 

 

2

Heat pump

 

 

3

E

Heat only (no fan) Auto Discover **

0174

Cooling compressor stages

1

1 stage of cool

[Other options: 0 or 2 stages, or E]

0176

Heat or Heat Pump Aux stages

1

1 stage of heat

[Other options: 0, 2 or 3 stages, or E]

0180

Fan control

0

Gas/Oil heat (equipment controls heating fan)

 

(conventional heat)

1

Electric furnace (thermostat controls heating fan)

 

 

2

E

Equipment controls stage 1, thermostat controls stage 2+ Auto Discover **

0190

Changeover valve

0

O/B terminal controls valve in cooling

 

(O/B terminal)

1

O/B terminal controls valve in heating

0200

Backup heat (Aux & EmHeat)

E

0

Auto Discover **

Electric backup heat

 

 

1

Fossil fuel backup heat

0210

External fossil

1

External fossil fuel kit controls backup heat

 

fuel kit

0

Thermostat controls backup heat (outdoor sensor required)

0220

Stage 1 compressor 1cycle rate

E

Auto Discover **

[Other options: 1 to CPH]

0230

Stage 2 compressor cycle rate

E

Auto Discover **

[Other options: 1 to 6 CPH]

0240

Stage 1 heat cycle rate (CPH= cycles per hour)

E

Auto Discover **

[Other options: 1 to 12 CPH]

0250

Stage 2 stage heat cycle rate (CPH)

E

Auto Discover **

[Other options: 1 to 12 CPH]

0260

Stage 3 heat cycle rate (CPH)

E

Auto Discover **

[Other options: 1 to 12 CPH]

0280

Backlight

0

Backlight on for approx. 45 seconds after keypress

 

 

1

Backlight always on low intensity, full bright after keypress

0300

Manual/Auto

0

Manual (User options: Heat/Cool/Off)

 

changeover

1

Automatic (User options: Heat/Cool/Auto/Off)

 

 

 

(System selects heat/cool based on indoor temp.)

0310

Auto changeover deadband

3

Heat/cool settings 3°F apart (1.5°C)

[Other options: 2-9 (2°F to 9°F/1°C to 5°C)]

0320

Temperature display

0

Fahrenheit

 

 

1

Celsius

0330

Daylight savings

2

 

1

Auto-change to daylight savings time (2007 and beyond, for areas that use the new 2007 DST calendar)

Auto-change to daylight savings time (through 2006, and for areas

 

 

 

0

that do not use the new 2007 DST calendar) Daylight savings time is turned off

0340

Indoor temp.

0

Display temp. at thermostat location only

 

sensor

1

Display temp. at indoor sensor location(s)

 

 

2

Average between thermostat & sensor location(s)

0342

Outdoor temp. sensor

E

0

Auto Discover **

None

 

 

1

Remote sensor

0345

Dual fuel heat

1

Balance point plus 2°F droop **

 

pump control

0

Balance point only **

 

 

2

Balance point/Aux Heat Lockout plus 2°F droop **

0346

Dual fuel heat

60

60 minutes **

 

pump upstage to furnace timer

0

Off

[Other options: 30, 45 or 75 minutes]

0350

Heat pump compressor lockout

0

No compressor lockout **

[Other options: 5 to 60°F (-15°C to 15.5°C)]

0360

Heat pump auxiliary lockout

0

No heat pump auxiliary lockout **

[Other options: 5 to 65°F (-15°C to 18.5°C)]

0365

Discharge temp. sensor

E

0

Auto Discover **

No

 

 

1

Yes

0370

Indoor humidity

1

Internal sensor in thermostat

 

sensor

0

E

Sensors disabled Auto Discover **

See The PDF Manual...

Error codes

027

Faulty thermostat (must be replaced)

035

Duplicate thermostat zone detected

036

Duplicate UV timer

037

Duplicate filter timer

038

Duplicate humidifier pad timer

039

Duplicate indoor humidity sensor

040

Compressor should be running but it is not

050

Duplicate outdoor temperature sensor

052

Faulty post-coil air discharge sensor

053

Faulty outdoor temperature sensor

054

Faulty indoor humidity sensor

089

Heating/cooling equipment is missing

090

Data interface is continuously busy

091

Thermostat is not receiving data from other equipment

118

Faulty discharge air temperature sensor

119

Faulty temperature sensor

121

Duplicate post-coil air discharge sensor

Accessories

Please contact your distributor to order replacement parts.

Outdoor temperature sensor Part number C7089U1006
Remote indoor temperature sensor Part number C7189U1005
Discharge air temp. sensor Part number C7835A1009
Energy recovery ventilator Part number ER200B2006
Heat recovery ventilator Part number HR200B1005
Fresh air damper Part number EARD6
2-Channel Telephone access module Part number W8735D1009
4-Channel Telephone access module Part number W8735D1017
Bypass flow-through or steam humidifier Part number HE265A1007
UV air purifier Part number UV100E1043
Cover plate Part number 32003796-001

(Use to cover marks left by old thermostats.)

*Contact your dealer or Honeywell rep for a complete list of compatible products.

Special function

  1. Auto Discover: Setup functions set to “E” (Auto Discover) will be configured automatically, based on information sent from connected equipment. When using Auto Discover, verify that the discovered value is correct. If it is not, the equipment is not communicating the information, and you must change settings manually.
  2. Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to “learn” how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the scheduled time.
  3. Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes before restarting, to prevent damage. During this time, the message “Wait” flashes on the display.
  4. Southern Away Dehumidification Control (Setup Functions 0390-0394): This feature is useful for homes in southern climates. It allows humidity control when the the home is unoccupied for long periods during the hot/humid season. You can control temperature (Function 0393) and dehumidification (Function 0394) while away. You can control humidity with a dehumidifier or a cooling system (Function 0379). If a cooling system is used, humidity is controlled by cooling indoor air to the Low Limit Temperature (Function 0392). When the desired humidity is reached, the system will maintain the temperature you select in Function 0393.
  5. Heat Pump Control — Electric Backup (Setup Functions 0350-0360): If an outdoor temperature sensor is installed, select a compressor lockout temperature (Function 0350). Below this temperature, only electric heat operates. Also select an auxiliary lockout temperature (Function 0360). Above this temperature, only the compressor operates. Between these temperatures, both heat sources operate.
  6. Heat Pump Control — Fossil Fuel Backup (Setup Function 0345):
    • Option 0 (Balance point only): If outdoor temperature is above balance point (Function 0350), only the compressor operates. Below this temperature, only backup heat operates.
    • Option 1 (Balance point + 2°F droop): As above, but backup heat is activated if room temperature drops by 2°F (compressor is deactivated).
    • Option 2: (Balance point/Aux Heat +2°F droop): Compressor works only above auxiliary lockout temperature, backup heat works only below balance point, 2°F droop between temperatures. If temperature is not reached in a reasonable time, set the upstage timer (Function 0346). After the designated time, the compressor will be deactivated and the system will switch to backup heat.
  7. Ventilation Control (Setup Functions 0400-0406): If the system includes a self-powered ventilation unit (Function 0400), the home can be ventilated on demand, or ventilated automatically if high humidity is detected while in heating mode (Function 0406).