Emerson White Rodgers NP110 Single-Stage Thermostat Manual
Emerson White Rodgers NP110 GUIDE CONTENTS
- Preparations
- Thermostat details
- Removal of your old thermostat
- Mounting and wiring your new thermostat
- Checking thermostat operation
- Specifications
- Troubleshooting
Emerson White Rodgers NP110 Operating features
Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.
- SIMULTANEOUS HEATING/COOLING SETPOINT STORAGE — You can enter both your heating and cooling setpoints at the same time. There is no need to re-enter the thermostat at the beginning of each season.
- TEMPERATURE SETTING — Press UP or Down Button until the display shows the temperature you want.
The thermostat will keep the room temperature at the selected temperature.
- °F/°C CONVERTIBILITY — The factory default setting is Fahrenheit. Clipping W904 jumper on the circuit board will alter this feature to Celsius temperature setting. See diagram on page 11.
- LOW BATTERY INDICATOR — If the 2 “AAA” alkaline batteries are low and should be replaced, the display will be blank except for Battery Indicator. When the batteries are low, pressing any button will cause the display to operate for ten seconds. After ten seconds, the display will be blank except for Battery Indicator . After Battery Indicator has been displayed for 4 weeks, the thermostat will raise the temperature 10° above your setpoint in COOL mode and drop the temperature 10° below your setpoint in HEAT mode. You cannot program with low batteries, but you can override setpoint temperature.
Emerson White Rodgers NP110 Terminal labeling reference chart
If your current terminal has the following letter |
Label the wires with the following letters |
Terminal function |
RH, R, R5, 5 |
RH |
24V Power (Heating) |
RC |
RC |
24V Power (Cooling) |
W, W1, 4 |
W |
Heating Relay |
Y, Y1 |
Y |
Cooling Relay |
G |
G |
Fan Relay |
O |
O |
Reversing Valve (for heat pump applications energized in Cool mode) |
B |
B |
Reversing Valve (for heat pump applications energized in Heat mode) |
Identify jumper wire
For terminal RC and RH:
On your old thermostat, if… |
Then, on your new thermostat… |
Terminal RC and RH are connected with a jumper wire |
Leave the jumper wire in its place |
There’s only one R wire (RC, RH, R or R5) coming out of the wall |
Leave the jumper wire in its place |
Terminal RC and RH (or 5 or R5) are NOT connected by a jumper wire |
Remove the jumper wire between RC and RH |
For terminal Y and W:
If you have a heat pump with reversing valve, connect Y and W with a jumper wire on your new thermostat.
Emerson White Rodgers NP110 SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
0 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F (0°C to 41°C)
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F (-40°C to 66°C)
Emerson White Rodgers NP110 TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation you can reset the thermostat by pressing UP and Down Button at the same time while moving the SYSTEM switch from OFF to HEAT. This also resets the factory defaults. If the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.
Batteries
For best results, replace batteries once a year with new premium brand alkaline batteries such as Duracell® or Energizer®.
Readmore and Download Emerson White Rodgers NP110 Single-Stage Thermostat Install Guide