ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Manual

ADEMCO VISTA SERIES  VISTA-20P / VISTA-20PSIA  VISTA-15P / VISTA-15PSIA Manual

ADEMCO VISTA SERIES PROGRAMMING MODE COMMANDS

Task

Command/Explanation

Go to a Data Field

Press [] + [Field Number], followed by the required entry.

Entering Data

When the desired field number appears, simply make the required entry. When the last entry for a field is entered, the keypad beeps three times and automatically displays the next data field in sequence. If the number of digits that you need to enter in a data field is less than the maximum digits available (for example, the phone number fields *41, *42), enter the desired data, then press [∗ ] to end the entry. The next data field number is displayed.

Review a Data Field

Press [#] + [Field Number]. 

Data will be displayed for that field number. No changes will be accepted in this mode.

Deleting an Entry

Press [] + [Field Number] + []. (Applies only to fields ∗40 thru *46, *94, and pager fields)

Initialize Download ID

Press 96. Initializes download ID and subscriber account number.

Reset Factory Defaults

Press 97. Sets all data fields to original factory default values.

Zone Programming

Press 56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF transmitters.

Function Key Programming

Press 57. Unlabeled keypad keys (known as ABCD keys) for special functions

Zone Programming (Expert Mode)

Press 58. Same options as *56 mode, but with fewer prompts. Intended for those familiar with this type of programming, otherwise *56 mode is recommended.

Output Device Mapping

Press 79. Assign module addresses and map individual relays/powerline carrier devices

Output Programming

Press 80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers

Zone List Programming

Press 81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.

Alpha Programming

Press 82. Zone alpha descriptors

Exit Program Mode with installer code lockout

Press 98. Exits programming mode and prevents  re-entry by:  Installer Code + 8 + 0 + 0.   To reenter programming mode, the system must be powered down, then powered up. Then use method A above. See field *88 for other *98 Program mode lockout options.

Exit Program Mode

Press 99. Exits programming mode and allows  re-entry by: Installer Code + 8 + 0 + 0 or method A above.

ADEMCO VISTA SERIES SPECIAL MESSAGES

OC = OPEN CIRCUIT (no communication between Keypad and Control).

EE or ENTRY ERROR = ERROR (invalid field number entered;  re-enter valid field number).

After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this delay by pressing [#] + [0]. 

If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after you correct the programming.

 

ADEMCO VISTA SERIES TABLE OF DEVICE ADDRESSES

This Device

Uses Address

Reports as ††

Enabled By…

RF Receiver

00

100

*56 zone programming: input device type entry

AUI 1

01

101

Automatic if AUI enable field *189 enabled for AUI 1

AUI 2

02

102

Automatic if AUI enable field *189 enabled for AUI 2

Long Range Radio

03

103

automatic if output to long range radio field *29 enabled

4286 Voice Module

04

104

automatic if phone module access code field *28 enabled

Zone Expanders (4219/4229):

module 1 (for zones 09 - 16)

module 2 (for zones 17 - 24)

module 3 (for zones 25 - 32)

module 4 zones 33 - 40

module 5 zones 41 - 48

 

07

08

09**

10**

11**

 

107

108

109

110

111

*56 zone programming: input device type entry, then: automatic if

zone no. 9-16 entered as AW type or relay assigned automatic if

zone no. 17-24 entered as AW type or relay assigned automatic if

zone no. 25-32 entered as AW type or relay assigned automatic if

zone no. 33-40 entered as AW type or relay assigned automatic

if zone no. 41-48 entered as AW type or relay assigned

Relay Modules (4204):

module 1 module

2 module 3 module 4

 

12

13

14**

15**

 

112

113

114

115

*79 output device programming: device address prompt:

entered at device address prompt entered at device

address prompt entered at device address prompt

entered at device address prompt

Keypads: keypad

1 keypad 2

keypad 3

keypad 4

keypad 5

keypad 6

keypad 7

keypad 8

 

16

17

18

19

20

21

22

23

n/a n/a

n/a n/a

n/a n/a

n/a 

n/a

data field programming as listed below: always

enabled, all sounds enabled.

data field *190

data field *191

data field *192

data field *193

data field *194

data field *195

data field *196

5800TM Module

28

n/a

automatic

ADEMCO VISTA SERIES Configurable Zone Types Worksheets 

Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182*185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software.

Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below. Use fields

*183 and *185 to program Contact ID report codes for these zone types.