ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Manual
ADEMCO VISTA SERIES PROGRAMMING MODE COMMANDS
Task |
Command/Explanation |
Go to a Data Field |
Press [∗] + [Field Number], followed by the required entry. |
Entering Data |
When the desired field number appears, simply make the required entry. When the last entry for a field is entered, the keypad beeps three times and automatically displays the next data field in sequence. If the number of digits that you need to enter in a data field is less than the maximum digits available (for example, the phone number fields *41, *42), enter the desired data, then press [∗ ] to end the entry. The next data field number is displayed. |
Review a Data Field |
Press [#] + [Field Number]. Data will be displayed for that field number. No changes will be accepted in this mode. |
Deleting an Entry |
Press [∗] + [Field Number] + [∗]. (Applies only to fields ∗40 thru *46, *94, and pager fields) |
Initialize Download ID |
Press ∗96. Initializes download ID and subscriber account number. |
Reset Factory Defaults |
Press ∗97. Sets all data fields to original factory default values. |
Zone Programming |
Press ∗56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF transmitters. |
Function Key Programming |
Press ∗57. Unlabeled keypad keys (known as ABCD keys) for special functions |
Zone Programming (Expert Mode) |
Press ∗58. Same options as *56 mode, but with fewer prompts. Intended for those familiar with this type of programming, otherwise *56 mode is recommended. |
Output Device Mapping |
Press ∗79. Assign module addresses and map individual relays/powerline carrier devices |
Output Programming |
Press ∗80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers |
Zone List Programming |
Press ∗81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc. |
Alpha Programming |
Press ∗82. Zone alpha descriptors |
Exit Program Mode with installer code lockout |
Press ∗98. Exits programming mode and prevents re-entry by: Installer Code + 8 + 0 + 0. To reenter programming mode, the system must be powered down, then powered up. Then use method A above. See field *88 for other *98 Program mode lockout options. |
Exit Program Mode |
Press ∗99. Exits programming mode and allows re-entry by: Installer Code + 8 + 0 + 0 or method A above. |
ADEMCO VISTA SERIES SPECIAL MESSAGES
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this delay by pressing [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after you correct the programming.
ADEMCO VISTA SERIES TABLE OF DEVICE ADDRESSES
This Device |
Uses Address |
Reports as †† |
Enabled By… |
RF Receiver |
00 |
100 |
*56 zone programming: input device type entry |
AUI 1 |
01 |
101 |
Automatic if AUI enable field *189 enabled for AUI 1 |
AUI 2 |
02 |
102 |
Automatic if AUI enable field *189 enabled for AUI 2 |
Long Range Radio |
03 |
103 |
automatic if output to long range radio field *29 enabled |
4286 Voice Module |
04 |
104 |
automatic if phone module access code field *28 enabled |
Zone Expanders (4219/4229): module 1 (for zones 09 - 16) module 2 (for zones 17 - 24) module 3 (for zones 25 - 32) module 4 zones 33 - 40 module 5 zones 41 - 48 |
07 08 09** 10** 11** |
107 108 109 110 111 |
*56 zone programming: input device type entry, then: automatic if zone no. 9-16 entered as AW type or relay assigned automatic if zone no. 17-24 entered as AW type or relay assigned automatic if zone no. 25-32 entered as AW type or relay assigned automatic if zone no. 33-40 entered as AW type or relay assigned automatic if zone no. 41-48 entered as AW type or relay assigned |
Relay Modules (4204): module 1 module 2 module 3 module 4 |
12 13 14** 15** |
112 113 114 115 |
*79 output device programming: device address prompt: entered at device address prompt entered at device address prompt entered at device address prompt entered at device address prompt |
Keypads: keypad 1 keypad 2 keypad 3 keypad 4 keypad 5 keypad 6 keypad 7 keypad 8 |
16 17 18 19 20 21 22 23 |
n/a n/a n/a n/a n/a n/a n/a n/a |
data field programming as listed below: always enabled, all sounds enabled. data field *190 data field *191 data field *192 data field *193 data field *194 data field *195 data field *196 |
5800TM Module |
28 |
n/a |
automatic |
ADEMCO VISTA SERIES Configurable Zone Types Worksheets
Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182*185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software.
Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below. Use fields
*183 and *185 to program Contact ID report codes for these zone types.
Readmore and Download ADEMCO VISTA SERIES Manual PDF
Title | : Download ADEMCO VISTA SERIES Manual PDF |
Format | |
Pages | : 25 Pages |
Language | : English |
File Size | : 3 MB |