Honeywell RTH111 Digital Non Programmable Thermostat User Manual Download
Identify System Type
This thermostat is compatible with the following systems:
- Gas, oil or electric furnace
- Central air conditioner
- Hot water system with or without pump
- Millivolt system
- Central heating and cooling system
- Heat pump without auxiliary/backup heat
Honeywell RTH111 Table of contents
- Installation
- Installation
- Advanced Installation
- About your new thermostat
- Controls and Home screen
- quick reference
- Compressor protection
- Replace batteries
- Appendices
- Troubleshooting
- Limited warranty
Honeywell RTH111 Installation
1. Turn Off Power to Heating/Cooling System
2. Remove Old Thermostat
3. Honeywell RTH111 Wiring (Label Wires with Tags)
Use the included cable label to mark the cable as you unplug it.
4. Separate Wallplate from New Thermostat
Remove the wall plate from the new thermostat and mount it on the wall.
5. Honeywell RTH111 Mount Wallplate
Install the new wall plate using the screws and anchors provided.
Drill 3/16-in. (4,76 mm ) holes for drywall
Drill 3/32-in. (2,38 mm ) holes for plaster
6, Honeywell RTH111 Connect Wires
Simply match wire labels.
If the label does not match the letters on the thermostat, check “Alternative wiring” on page 6 and connect to the terminals as shown (see note below).
Alternate Wiring
If the labels do not match the letters on the thermostat, check the diagram below and connect to the terminals as shown here (see note below).
- If the wires are connected to terminals R and Rc, remove the metal jumpers.
- Do not use C or X. Wrap electrical tape around the bare ends of the wires.
- If you have a heat pump without additional/backup heating, connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap the bare ends of the wires with electrical tape.
- Place a bridge (a piece of wire) between the Y and W if you are using a non-add/post-heat heat pump.
7. Honeywell RTH111 Install Batteries
Install two AAA alkaline batteries
8. Honeywell RTH111 Set fan operation switch
Move the switch to the proper setting:
Gas or Oil: In the case of gas or oil heaters, leave the fan operation switch in this factory setting (for systems that control the fan when heat is required).
Electric or Heat Pump: Change this setting switch for heat pumps or electric heating systems. (This setting applies to systems that allow the thermostat to control the fan when heat is required when the fan cable is connected to terminal G.)
9. Install Thermostat onto Wallplate
Install the thermostat on the wall plate.
10. Turn Power Back On
Reconnect or turn power to the heating/cooling system.
Honeywell RTH111 Troubleshooting
If you are having problems with the thermostat, please try the following suggestions. Most problems can be fixed quickly and easily.
Display is blank
- Make sure fresh AAA alkaline batteries are correctly installed.
Heating or cooling system does not respond
- Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature.
- Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
- Wait 5 minutes for the system to respond.
Cannot change setpoint
Verify the system switch is set to Heat or Cool mode. The thermostat should allow you to change the setpoint within the following ranges:
- Heat: 40° to 90°F (4.5° to 32°C).
- Cool: 50° to 99°F (10° to 37°C).
“Cool On” or “Heat On” is flashing
- Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.
“Heat On” is not displayed
- Set the System switch to Heat, and set the temperature level above the current room temperature.
“Cool On” is not displayed
- Set the System switch to Cool, and set the temperature level below the current room temperature.
Honeywell RTH111 Electrical Ratings
Terminals |
Voltage (50 Hz/60 Hz) |
Running Current |
W Heating |
20 VAC-30 VAC |
1.0 A |
W Power Pile Heating |
750 mV DC |
100 mA DC |
Y Compressor |
20 VAC-30 VAC |
1.0 A |
O Changeover, Cooling |
20 VAC-30 VAC |
0.5 A |
B Changeover, Heating |
20 VAC-30 VAC |
0.5 A |
G Fan |
20 VAC-30 VAC |
0.5 A |