Identify System Type

This thermostat is compatible with the following systems:

  • Gas, oil or electric furnace
  • Central air conditioner
  • Hot water system with or without pump
  • Millivolt system
  • Central heating and cooling system
  • Heat pump without auxiliary/backup heat

Honeywell RTH111 Table of contents

  • Installation
    • Installation
    • Advanced Installation
  • About your new thermostat
    • Controls and Home screen
    • quick reference
    • Compressor protection
    • Replace batteries
  • Appendices
    • Troubleshooting
    • Limited warranty

Honeywell RTH111 Installation

1. Turn Off Power to Heating/Cooling System

Honeywell RTH111 Installation

2. Remove Old Thermostat

Honeywell RTH111 Installation Manual

3. Honeywell RTH111 Wiring (Label Wires with Tags)

Use the included cable label to mark the cable as you unplug it.

Honeywell RTH111 Wiring

4. Separate Wallplate from New Thermostat

Remove the wall plate from the new thermostat and mount it on the wall.

Honeywell RTH111 Walplate

5. Honeywell RTH111 Mount Wallplate

Install the new wall plate using the screws and anchors provided.

Honeywell RTH111 Mount Wallplate

Drill 3/16-in. (4,76 mm ) holes for drywall
Drill 3/32-in. (2,38 mm ) holes for plaster

6, Honeywell RTH111 Connect Wires

Simply match wire labels.
If the label does not match the letters on the thermostat, check “Alternative wiring” on page 6 and connect to the terminals as shown (see note below).

Honeywell RTH111 Connect Wires

Alternate Wiring
If the labels do not match the letters on the thermostat, check the diagram below and connect to the terminals as shown here (see note below).

Honeywell RTH111 Alternate Wiring

  • If the wires are connected to terminals R and Rc, remove the metal jumpers.
  • Do not use C or X. Wrap electrical tape around the bare ends of the wires.
  • If you have a heat pump without additional/backup heating, connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap the bare ends of the wires with electrical tape.
  • Place a bridge (a piece of wire) between the Y and W if you are using a non-add/post-heat heat pump.

7. Honeywell RTH111 Install Batteries

Install two AAA alkaline batteries 

Honeywell RTH111 Install Batteries

8. Honeywell RTH111  Set fan operation switch

Move the switch to the proper setting:
Gas or Oil: In the case of gas or oil heaters, leave the fan operation switch in this factory setting (for systems that control the fan when heat is required).
Electric or Heat Pump: Change this setting switch for heat pumps or electric heating systems. (This setting applies to systems that allow the thermostat to control the fan when heat is required when the fan cable is connected to terminal G.)

Honeywell RTH111  Set fan operation switch

9. Install Thermostat onto Wallplate

Install the thermostat on the wall plate.

Honeywell RTH111 Install Thermostat onto Wallplate

10. Turn Power Back On

Reconnect or turn power to the heating/cooling system.

Honeywell RTH111 turn back ON system

Honeywell RTH111 Troubleshooting

If you are having problems with the thermostat, please try the following suggestions. Most problems can be fixed quickly and easily.

Display is blank

  • Make sure fresh AAA alkaline batteries are correctly installed.

Heating or cooling system does not respond

  • Set system switch to Heat. Make sure the temperature is set higher than the Inside temperature.
  • Set system switch to Cool. Make sure the temperature is set lower than the Inside temperature.
  • Wait 5 minutes for the system to respond.

Cannot change setpoint

Verify the system switch is set to Heat or Cool mode. The thermostat should allow you to change the setpoint within the following ranges:

  • Heat: 40° to 90°F (4.5° to 32°C).
  • Cool: 50° to 99°F (10° to 37°C).

“Cool On” or “Heat On” is flashing

  •  Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor.

“Heat On” is not displayed

  • Set the System switch to Heat, and set the temperature level above the current room temperature.

“Cool On” is not displayed 

  • Set the System switch to Cool, and set the temperature level below the current room temperature.

Honeywell RTH111 Electrical Ratings 

Terminals

Voltage (50 Hz/60 Hz)

Running Current

W Heating

20 VAC-30 VAC

1.0 A

W Power Pile Heating

750 mV DC

100 mA DC

Y Compressor

20 VAC-30 VAC

1.0 A

O Changeover, Cooling

20 VAC-30 VAC

0.5 A

B Changeover, Heating

20 VAC-30 VAC

0.5 A

G Fan

20 VAC-30 VAC

0.5 A