Honeywell Thermostat CT1500 User Manual

Honeywell Thermostat CT1500 User Manual

This is for manual about CTl500, CT1501, CT1502, CT1503 ELECTROMECHANICAL FUEL SAVER THERMOSTAT AND WALLPLATEEUBBASE
CTI500-24 V gas or oil heat.
CTl501-24 V gas or oil heat/cool.
CTI502--24 V central electric heat/cool or single stage heat pump without auxiliary heat.
CTI 503-750 millivolt heat.
NOT FOR USE ON LINE VOLTAGE (120 V) SYSTEMS

SET TIMER Honeywell Thermostat CT1500

SET TIMER Honeywell Thermostat CT1500

  • Adjust the timer by moving the knob in clockwise direction. Do NOT reverse the knob.
  • When time is correctly set, the Time Indicator Arrow (see illustration) must point to the correct time and the corresponding daytime (lighr) or nighitime (dark) portion of the program dial.

Honeywell Thermostat CT1500 Series Heating-only System

  • Turn on power to the furnace.
  • Push both temperaturecontrol leverstogetherat least 5" F [3" C] above room temperature. The heat should comeon.Thefan will startwhen the furnace heats up.
  • Move both levers5" F [3" C] below room temperature. The heat should shut off.
  • Operate the entire heating system for at least one complete cycle.

Honeywell Thermostat CT1500 Series Heating /Cooling System

  • Turn on power to the furnace and cooling system.
  • Place the system switch lever at HEAT and the fan switch lever at AUTO.
  • Push both temperaturecontrol leverstogetherat least 5'F [3"C] above room temperature. The heat should comeon.Thefan will startwhen the furnace heats up. On the CT1502, the fan will start immediately.
  • Moveboth leverstogether5"F[3"C]belowroom temperature. The heat should shut off. The fan will stop when the furnace cools.
  • Place the system switch lever at COOL and the fan switch lever at AUTO.
  • Push both temperature control levers together at least 5 O F [3" C] below room temperature. Thecooling equipment should operate, and the fanwill start. Allow for any time delay that may bebuilt into the compressor control circuit.
  • Movebothleverstogether5°F[30C]aboveroom temperature. The cooling equipment should shut off.
  • Place the fan switch at ON. The fan should run continuously with the system switch in any position.
  • Place the system switch at OFF. Move both temperature: levers to various positions. The heating andcooling systems should not operate.
  • Operate the entire system for at least one complete cycle with the system switch at COOL and one complete cycle with the switch at HEAT.