LUX LV11 Installation and Operating Instructions

LUX LV11 Thermostat Manual PDF

A single pole, line voltage manual thermostat that offers ease of use. For heat only. The LV11 is a single-pole heat only, manual thermostat that is easy to install and use. With a clean attractive design this unit is unobtrusive while providing features to enhance your system. As with the complete Lux thermostat line, this unit is mercury free

LUX LV11 Spesification

  • UPC: 0 21079 00262 7
  • Dimensions width: 4.56" (115.8mm)
  • Dimensions height: 2.81" (71.3mm)
  • Dimensions depth: 2.31" (51.6mm)
  • Non-programmable single pole line voltage -heat only

LUX LV11 Features

  • Easy installation
  • Easy to use
  • 3 year warranty
  • UL approved
  • Mercury free
  • For Use On 1 stage heat only: single pole, 120/240 VAC Systems up to 22 AMPS and Not Fore Use On Conventional 24V heating and cooling

LUX LV11 INSTALLATION INSTRUCTIONS:

  1. Disconnect the supply power before removing your old thermostat (if applicable), and keep it off until after you have completed the installation.
  2. If replacing an old thermostat, remove it carefully to avoid damaging the wires or the insulation.  Check the existing wire insulation for cracks, nicks, or fraying.  Apply electrical tape where necessary to achieve adequate insulation, or replace the wires in an approved fashion.
  3. Be sure to use the appropriate wires on the thermostat: the RED thermostat wires shall be connected to the voltage supply wires from the circuit breaker, and the BLACK thermostat wires shall be connected to the wires going to the heating appliance.
  4. Perform the wire connections using appropriately sized solder-less wire connectors (provided), and be sure that ALL wire connections are securely tightened.
  5. Carefully bend any excess wire length into the rear of the electrical box to allow enough room for the thermostat to be comfortably secured to the wall box without having to force it.  Ensure that the wires are positioned so that the mounting screws will not damage the wire insulation when they are installed.
  6. Once complete, turn the power back on to your heating equipment at the circuit breaker and confirm proper heating operation in all thermostat dial positions.

LUX LV11 Troubleshooting

Troubleshooting Poor Temperature Regulation

  • This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions.
  • For more detailed information please refer to the instructions that came with your thermostat.

Model

LV1 / LV11

Problem

Resolution

 

Verify that your thermostat's electrical connections are clean and tight.

 

Heats more than 5 degrees past its displayed set temperature

Verify that your units placement and mounting are optimum per the installation section of its manual.

Slowly rotate the dial from full left to full right. Listen carefully for a small click in both directions. These two clicks should be near the approximate room temperature location on the knob.

 

Replace unit. There are no user serviceable parts.

 

Refer to wiring troubleshooting to verify that it is wired according to the units proper wiring diagram. Verify that all connections to your thermostat are clean and tight.

No heat when expected

If room temperature is greater than 90F the unit will not close its switch and call for heat.

 

Rotate the dial to its highest setting. Heat should operate immediately if the approximate room temperature is less than around 90F degrees.

Heat Test

Slowly rotate the dial toward its lowest setting. Listen carefully for a small click near room temperature. When it is heard, the unit should switch off heat immediately. Slowly rotate the dial toward its higest setting. Listen carefully for a small click near room temperature. When it is heard, the unit should switch on heat immediately.

 

This thermostat is designed to switch hazardous voltage. Qualified service personnel may use the following information to troubleshoot the system.

Advanced Troubleshooting

The thermostat uses a single-pole snap-action switch to control heating output. It should open when the room is warmer than its set temperature, close when cooler than its set temperature. At its minimum setting, the switch should remain open at any temperature within its operating range, unless the room temperature is less than about 40-50F degrees.

Wiring Information and Troubleshooting

  • This page provides general guidance for your LUX Line Voltage mechanical thermostat. For more detailed information please refer to the instructions that came with your thermostat.
  • Please make specific note regarding LOW VOLTAGE and LINE VOLTAGE directions. Do not install LINE VOLTAGE wires to a LOW VOLTAGE control.
  • Do NOT wire by color of the wire, wire by the LETTER designation to which the wire was attached on the previous control.
  • If there were no letterdesignations on your old thermostat, contact our Technical Assistance Department for assistance.

Model

LV1 / LV11

Problem

Resolution

 

DO NOT ATTACH LINE VOLTAGE WIRES TO A LOW VOLTAGE THERMOSTAT.

120 VAC or 240 VAC connected to previous control

Although its installation is relatively simple, this thermostat is designed to switch hazardous voltage. If you are unsure of any aspect of this products application or installation consult with our technical assistance personnel, or other qualified service personnel for assistance.

 

Carefully follow the included wiring instructions for the line voltage heating thermostat.

 

Verify that your thermostat's electrical connections are clean and tight.

No heat when expected

If your house wiring at the thermostat location has aluminum wiring, the included wire nuts cannot be used and will be a potential fire hazard; these are for use with copper house wiring only. Special CO/ALR wire connectors made spefically for aluminum must be used; please seek the assistance from a competent licensed electrician for more information.

For further assistance:

Contact your HVAC service company or our Technical Assistance Line if not resolved.