Trane XR402 Thermostat Manual
TCONT402AN32DA 3 Heat (Gas, Oil* or Elec) / 2 Cool / Heat Pump, Dual Fuel (Factory set for 2H/2C gas/cooling applications, BK Output enabled) Electronic Non-Programmable 3 - 16 Wire Hookup (2 for Outdoor Sensor) (2 for Optional Remote Indoor Sensor, 2 for Optional Humidistat).
Trane XR402 Thermostat Introduction
TCONT402AN32DA is a digital non-programmable 3Heat/ 2 Cool/Heat Pump/ Heat-Cool wall mounted low voltage (24VAC) Comfort Control with backlit LCD and keypad. It maintains room temperature by controlling the operation of heating, cooling, heat pump and dual fuel systems. The Comfort Control is easily configured for heat pump or cooling only and gas or electric or dual fuel heat applications via the user friendly Installer Setup menu. The Comfort Control features include separate heating and cooling setpoints, selectable auto or manual changeover, adjustable energy saving mode, adjustable filter reminder, outdoor temperature sensing, remote room sensing and remote humidistat input. Setup selections and diagnostics are stored indefinitely in the Comfort Controls nonvolatile memory eliminating the need for battery backup.
Trane XR402 Thermostat Product Specifications
- Power Source: 20-30VAC, Class II, 50/60Hz.
- System Mode: Heat, Cool, Auto, Emergency Heat and Off
- Fan Mode: Auto and On
- Cooling setpoint temperature range: 65°F - 90°F, 18.0°C - 33.0°C, 1°F and 0.5°C resolution.
- Heating setpoint temperature range: 40°F- 85°F, 5.0°C - 30.0°C, 1°F and 0.5°C resolution.
- Default set points: 68°F, 20.0°C Heat, 78°F, 25.5°C Cool
- Storage Range: -40°F to 140°F, 5% - 90% RH non-condensing.
- Operating Temperature range: 32°F - 110°F, 5% - 90% RH non-condensing.
- Outdoor Temperature Display Range: -40°F - 140°F.
- Minimum Cycle Off Time Delay: Cooling - 5 minutes, Heating - 1 minute.
- Use minimum 18 gauge NEC approved control wiring.
Trane XR402 Thermostat Application Hook Up Diagrams
Dual Fuel* | FIG | ||
1-2 Stage/Step Heat Pump 2 Stage Heat Pump 2 Step Heat Pump 1 Stage Heat Pump 1 Stage Heat Pump |
2 Stage VS Gas Furnace 2 Stage VS Gas Furnace 2 Stage VS Gas Furnace 2 Stage VS Gas Furnace 1-2 Stage Non-VS Gas Furnace |
w/ BK no BK no BK no BK no BK |
DF-1 DF-2 DF-3 DF-4 DF-5 |
Heat Pump | |||
1-2 Stage/Step Heat Pump 2 Stage Heat Pump 2 Step Heat Pump 2 Heat Pumps Split Coil 2 Heat Pumps Split Coil 1 Stage Heat Pump 1 Stage Heat Pump |
VS Air Handler VS Air Handler HP-4 VS Air Handler VS Air Handler VS Air Handler VS Air Handler Non-VS Air Handler |
w/ BK no BK no BK w/ BK no BK no BK no BK |
HP-1 no BK HP-5 HP-2 HP-3 HP-6 HP-7 |
Cooling | |||
1-2 Stage/Step Cooling 2 Stage Cooling 2 Step Cooling 2 Cool Units Split Coil 2 Cool Units Split Coil 1 Stage Cooling 1 Stage Cooling 1 Stage Cooling 1 Stage 1 Stage Heat Pump 1-2 Stage/Step Heat Pump |
VS Indoor VS Indoor VS Indoor VS Air Handler VS Air Handler VS Indoor Non-VS Indoor Non-VS Oil Furnace Non-VS Oil Furnace VS Oil Furnace |
w/ BK no BK no BK w/ BK no BK no BK no BK no BK no BK w/ BK |
CL-1 CL-3 CL-4 CL-2 CL-5 CL-6 CL-7 OIL-1 OIL-2 OIL-3 |
* Requires external relay for Oil furnace applications. TAYPLUS103 not required BAYSENS01ATEMPA for outdoor temperature sensing and display and optional control is included.
Optional Humidistat: BAYSTAT253A
Optional Remote Indoor Sensor: ZZSENSAL0400AA